What is wrong
Halcore Group, Inc. (Halcore) is recalling certain 2016-2019 Horton Emergency Vehicles Type I and Type III ambulances. The A/C input power cord for the Sensata inverter may be undersized for certain inverter applications, possibly resulting in an electrical short circuit.
What can happen
An electrical short circuit increases the risk of a fire or a shock hazard.
The fix
Recall repairs are free of charge.
Halcore has notified owners, instructing them to contact Sensata for a replacement power cord, free of charge. The recall began March 10, 2020. Owners may contact Halcore customer service at 1-800-447-0343.
Vehicles covered
2 models, 8 model years in all
Related pages
Questions and answers
Which vehicles are in recall 20V128000?
2 models: Horton Type I (2016-2019), Horton Type III (2016-2019), about 18 vehicles in all.
What is the fix for recall 20V128000?
Halcore has notified owners, instructing them to contact Sensata for a replacement power cord, free of charge. The recall began March 10, 2020. Owners may contact Halcore customer service at 1-800-447-0343.
What can happen?
An electrical short circuit increases the risk of a fire or a shock hazard.
A recall means the maker found a safety problem and offers a free fix; it does not mean every unit has the problem. Units affected are as reported by the company. Popular models sell more and so have more recalls and complaints. Official public data; texts are shortened. A dealer can tell whether a single vehicle still needs the repair.