Gillig LOW Floor, Phantom (1997-2000): Structure
Recall 02V059004 · Mar 21, 2002 · Gillig Corporation
897
vehicles affected
897
vehicles affected
Facts
- Recall number
- 02V059004
- Date
- Mar 21, 2002
- Maker
- Gillig Corporation
- Units affected
- 897
- Kind
- Vehicles
- Component
- Structure > Body > Door
- Model years
- 1997-2000
- Started by
- The safety regulator
- Hazard
- Falls
What is wrong
ON CERTAIN TRANSIT BUSES EQUIPPED WITH ADHESIVELY BONDED ALUMINUM BUS DOOR PANELS, DUE TO AN IMPERFECT BONDING OF THE DOOR PANEL SKIN TO THE PANEL FRAME, ENVIRONMENTAL MOISTURE MAY INFILTRATE REGIONS OF IMPERFECT BONDING AND CAUSE SEPARATION OF THE FRAME AND DOOR PANEL.
What can happen
UNDER THESE CONDITIONS, IF THE PANEL IS SEPARATING OR HAS SEPARATED, A PASSENGER COULD FALL FROM THE BUS ONTO THE ROADWAY, POSSIBLY RESULTING IN PERSONAL INJURY OR DEATH.
The fix
Recall repairs are free of charge.
VAPOR WILL NOTIFY CUSTOMERS TO HAVE THEIR BUSES INSPECTED AND WILL INSTALL MECHANICAL FASTENERS TO ATTACH THE SKINS TO THE FRAME ELEMENTS FREE OF CHARGE. OWNERS WHO DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT VAPOR CORPORATION AT 847-967-8300 OR VAPOR AT 1510-785-1500.
Vehicles covered
2 models, 8 model years in all
This recall in context
Compared with other Gillig recalls and the Gillig Low Floor's own record
- 5 Gillig recalls were issued in 2002, up from 1 in 2001.
- By vehicles covered, this recall is the 4th largest of the 5 Gillig recalls of 2002 with a reported number.
- Gillig vehicles have been recalled 116 times in the data since 1970.
- The Gillig Low Floor has 92 recalls in all; 5 of them concern structure.
- Owners filed 1 safety complaints about the 1997-2000 Gillig Low Floor, the model years this recall covers.
More on the Gillig Low Floor page: recalls and complaints by year, crash test ratings and how it compares with other Gillig models.
Other Gillig Low Floor recalls
Recalls of the same part (structure) first, then the newest
| Date | Recall | Vehicles |
|---|---|---|
| Dec 15, 2025 | Gillig LOW Floor (2013): Structure | 6 |
| Apr 23, 2021 | Gillig BRT, LOW Floor (2020-2021): Structure | 229 |
| Jun 14, 2019 | Gillig LOW Floor (2018-2019): Structure | 25 |
| Dec 12, 2018 | Gillig LOW Floor (2016-2017): Structure | 30 |
| Nov 18, 2026 | Gillig LOW Floor (2023-2026): Electrical system | 1,323 |
| Oct 23, 2026 | Gillig LOW Floor (2021-2026): Fuel system, diesel | 1,853 |
Related pages
Questions and answers
Which vehicles are in recall 02V059004?
2 models: Gillig Low Floor (1997-2000), Gillig Phantom (1997-2000), about 897 vehicles in all.
A recall means the maker found a safety problem and offers a free fix; it does not mean every unit has the problem. Units affected are as reported by the company. Popular models sell more and so have more recalls and complaints. Texts are shortened. A dealer can tell whether a single vehicle still needs the repair.